Sierra Wireless Writing an embedded application loader Instrukcja Użytkownika Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 22
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
IndustrialPro™ and MobilityPro™ Gateway Wireless Modems
BT Series Firmware Release Notes
Sixnet, Inc. FLEXIBLE. RELIABLE. POWERFUL.
331 Ushers Road, Ballston Lake, NY 12019 T +1 518 877 5173 F +1 518 877 8346
www.sixnet.com
Version 3.8.12 © 2012. Sixnet. All Rights Reserved.
17
Fixed Issues
ID
Subject
Description
898
WAN
Traffic from USB causes WAN to disconnect
when in IP pass
-
through
902 Events
Incorrect event ACK in UDP causes
reporting destination to change
This was an issue when the BEP server did not use the same port for source and
destination.
1074
Events
Modem does not report signal strength in EVDO
-
only mode
1081 GPS
GPS sensitivity
Improve GPS stationary detection, especially for Copernicus firmware 3.02 and
Copernicus II firmware 1.04.
1093
Events
BEP: BT
-
5400 reports 0 as device ID
1091 GPS
Close GPS port 9999
.
The modem GPS server port may be re-opened with AT+BGPSSV
1119 DUN
Dial
-
up Networking (DUN)
PC failed to connect after a few connect/disconnect cycles.
1120
Apps
Partner apps: No access to localhost when in IP pass
-
through
1122
Support for BT
-
4600/BT
-
5600 (EVDO rel. 0)
Re-introduce support for those models (broken in 3.8.3)
1123
Apps
Internal con
nections to tcp:5070/tcp:6070 when AT password is enabled
1124
Events
BEP RSSI value in RF2 payload
The value is now coded according to specification (positive in RF2 and negative in RF1).
1127 GPS
GPS reporting to IP destination faster than
the valu
e specified in the
reporting timer
of
AT+BGPSPR.
1128
Events
MOM:
Modem jobs fail when configured with UDP
1129
Apps
Partner apps: last reserved port not configured
1131
Serial IP
Listening server hangs when client disconnects
1133
Events
MOM: mul
tiple re
-
transmissions of TCP/IP BEP packets
1134 AT
AT commands: timeout and out of sequence
From time to time the modem AT interface fails until the modem is restarted.
1135
Events
+BEVENT: "WAN" signal trigger is missing
The WAN signal trigger of AT+BEVENT was documented but not implemented.
1140
Apps
Partner apps: Frequent app enabling/disabling breaks AT commands
1141
WAN
+BMDIAG does not show correct WAN IP address
The WAN IP address in AT+BMDIAG is occasionally prefixed with the string 'ppp'. When
this happens, AT+BIPINF fails (returns ERROR) and the modem cannot communicate on
its WAN interface.
1144
Events
+
BEVAIS value2 parsed as an integer instead of a float
Correctly parse the two values of the comparison expression.
1146
Di
agnostics
EVDO modems fail pass
-
through to RF diagnostic port (DM)
1148
AT
ATO occasionally does not return modem to Serial IP mode
1149
AT
Long AT responses not entirely written on serial port
Przeglądanie stron 16