Sierra Wireless AirLink FXT Series Dokumentacja Strona 39

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 38
WA_DEV_FEX20_PTS_004 Rev 001 June 30, 2010 39
Expansion Card Product Technical
Specification
Reliability Compliance and
Recommended Standards
Table 39: Environmental Resistance Stress Test
Designation
Condition
Cold Test
COT
Standard: IEC 680068-2-1, Test Ab
Special conditions:
Temperature: -40°C
Rate of temperature change: dT/dt >= ± 3°C/min
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 72 hours
6.3.2.3. Corrosive Resistance Stress Test
The following tests the Fastrack Xtends resistance to corrosive atmosphere.
Table 40: Corrosive Resistance Stress Test
Designation
Condition
Moist Heat Cyclic Test
MHCT
Standard: IEC 60068-2-30, Test Db
Special conditions:
Upper temperature: +55 ± 2°C
Lower temperature: +25 ± 2°C
RH:
Upper temperature: 93%
Lower temperature: 95%
Number of cycles: 21 (1 cycle/24 hours)
Rate of temperature change: dT/dt >= ± 3°C/min
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 21 days
Przeglądanie stron 38