AirLink GX400 for Verizon User Guide
44 2140712
Power Effect on Device State
Once the transition from powered on to low-power mode starts, the device will
change state to AT mode. This results in the current mode being gracefully
terminated. For the brief period when the device is preparing for low-power mode,
the device will remain in AT mode. At that time, it will not auto-answer, ATD will
fail, etc. Once low-power mode is entered, the device will then discard any data
received on the host port.
When the device is activated from low-power mode, the same behavior occurs as
power on. The device starts in AT mode, and after 5 seconds will enter the default
start-up mode as it is configured for in the device.
Monitoring Power-In Voltage
The current status of the power-in voltage can be monitored in ACEmanager.